THERMAL SCIENCE

International Scientific Journal

LOW-PRESSURE REVERSIBLE AXIAL FAN DESIGNED WITH DIFFERENT SPECIFIC WORK OF ELEMENTARY STAGES

ABSTRACT
Low-pressure axial fan impellers designed according to the principle of equal specific work of all elementary stages have blades whose profile near the fan hub is under a significantly larger inclination angle than at the impeller periphery. In order to minimize the spatial curvature of the fan blades and the fan hub length, impeller blades of low-pressure axial fans can be designed with different specific work of elementary stages, so that the specific work of elementary stages is smaller at the hub than at the periphery. This paper presents the operating characteristics of a low-pressure reversible axial fan with straight blade profiles, designed with different specific work of elementary stages. The fan was tested on a standard test rig, with air intake loading on the suction side of the fan.
KEYWORDS
PAPER SUBMITTED: 2012-05-03
PAPER REVISED: 2012-07-04
PAPER ACCEPTED: 2012-07-12
DOI REFERENCE: https://doi.org/10.2298/TSCI120503195B
CITATION EXPORT: view in browser or download as text file
THERMAL SCIENCE YEAR 2012, VOLUME 16, ISSUE Supplement 2, PAGES [S605 - S615]
REFERENCES
  1. Bogdanovi. B., Bogdanovi.-Jovanovi. J., Spasi. .., Designing of low pressure axial flow fans with different specific work of elementary stages, Proceedings on CD, The international conference Mechanical Engineering in XXI Century, 25.26. XI 2011, Faculty of Mechanical Engineering Nis, Serbija, pp. 99-102.
  2. Spasi. .., Numerical and Experimental Investigation of the Influence of the Blade Profile Shape on the Reversible Axial Fan Characteristics (in Serbian), Ph. D. thesis, Faculty of Mechanical Engineering Nis, University of Nis, Nis, 2012
  3. Bogdanovi. B., et al., The Development Construction of Reversible Axial Fans (in Serbian), Report for project No. 18012, funded by the Ministry of Science and Technological Development, the period: 31.04.2008.31.04.2011.
  4. „Eck B., Fans-Design and Operation of centrifugal, axial-flow and cross-flow fans, Pergamont Press, Oxford, England, 1973.
  5. Spasi. .., Bogdanovi. B., Radi. M., Variation of operation of low-pressure reversible axial fans driven by induction motor from start to the steady-stat, Proceedings on CD, SIMTERM 2011, Sokobanja, 18- 21,10.2011, pp. 586-595.
  6. Bogdanovi. B., Milenkovi. D., Bogdanovi.-Jovanovi. J., Fans-performance and operating characteristics (in Serbian) Faculty of Mechanical Engineering Nis, 2012.

© 2024 Society of Thermal Engineers of Serbia. Published by the Vinča Institute of Nuclear Sciences, National Institute of the Republic of Serbia, Belgrade, Serbia. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International licence