ABSTRACT
In this study, the convective drying process on the stenter machine used natural gas as fuel was examined in terms of energy saving. The fuel consumption in the drying process of wool fabric with and without heat recovery from exhaust air of stenter was determined. It was shown that the fuel consumption in stenter can be decreased significantly by the use of heat recovery exchangers. According to the results minimum fuel consumption was observed at inlet drying air temperature of 180°C and humidity ratio of the exhaust air of 0.08 kgy/kga. In this condition fuel consumption decreased from 205.3 m3/h to 177.3 m3/h by using heat recovery exchanger. The fuel consumption of drying systems reduced by 13.6%.
KEYWORDS
PAPER SUBMITTED: 2019-05-10
PAPER REVISED: 2019-08-16
PAPER ACCEPTED: 2019-08-29
PUBLISHED ONLINE: 2019-09-15
DOI REFERENCE: https://doi.org/10.2298/TSCI190510336C
CITATION EXPORT: view in browser or download as text file
THERMAL SCIENCE YEAR 2021, VOLUME 25, ISSUE Issue 2, PAGES [1047 - 1055]
REFERENCES
  1. Cay, A., et al., Exergetic Performance Assessment of a Stenter System in a Textile Finishing Mill, Int. J. Energy Res., 31 (2007), 13, pp. 1251-1265
  2. Santos, R. M, et al., Study of Drying and Consumption of Natural Gas in a Textile Stenter of Direct Heating, Drying Technology, 33 (2015), 1, pp. 37-54
  3. Johann, G., et al., Mathematical Modelling of a Convective Textile Drying Process, Brazilian Journal of Chemical Engineering, 31 (2014), 4, pp. 959-965
  4. Dincer, I., Sahin, A. Z., A New Model for Thermodynamic Analysis of a Drying Process, International Journal of Heat and Mass Transfer, 47 (2004), 4, pp. 645-652
  5. Xue, L., Process Optimization of Dryers/Tenters in the Textile Industry, M. Sc. thesis, Georgia Institute of Technology, Atlanta, Geo., USA, 2004
  6. Cay, A., et al., Exergetic Analysis of Textile Convective Drying with Stenters by Subsystem Models, Drying Technology, 28 (2010), 12, pp. 1359-1367
  7. Ceylan, H., Gelir, B., Energy and Economical Analysis of Heat Recovery Exchanger Design for Stenter Machine, Journal of TTMD, 110 (2017), pp. 28-32
  8. Fiaschi, D., et al., Improvement of Waste Heat Recuperation on an Industrial Textile Dryer Redesign of Heat Exchangers Network and Components, Energy Conversion and Management, 150 (2017), Oct., pp. 924-940

© 2024 Society of Thermal Engineers of Serbia. Published by the Vinča Institute of Nuclear Sciences, National Institute of the Republic of Serbia, Belgrade, Serbia. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International licence