THERMAL SCIENCE

International Scientific Journal

CORRELATIONS TO PREDICT THERMAL PERFORMANCE AFFECTED BY WORKING FLUID’S PROPERTIES OF VERTICAL AND HORIZONTAL CLOSED-LOOP PULSATING HEAT PIPE

ABSTRACT
Objectives of this paper are to investigate the effects of dimensionless numbers on the thermal performance, and to establish correlations to predict the thermal performance of the vertical and a horizontal closed-loop pulsating heat pipe. The heat pipes were made of long copper capillary tubes with 26 meandering turns and both the ends were connected together to form a loop. R123, R141b, acetone, ethanol, and water were chosen as variable working fluids with a constant filling ratio of 50% by total volume. The inlet temperature of the heating medium and the adiabatic section temperature were constantly controlled and maintained at 80°C and 50°C, respectively. The thermal performance was represented in terms of the Kutateladze number. It can be concluded that when the Prandtl number of the liquid working fluid, as well as the Karman number, increases, the thermal performance increases. On the other hand, when the Bond number, the Jacob number, and the Aspect ratio increase, the thermal performance decreases. These effects of the dimensionless numbers on the thermal performance are valid for both the heat pipes, except in the case of Bond number which has no effect on the thermal performance as far as the horizontal heat pipe is concerned. Moreover, correlations to predict thermal performance have been successfully established.
KEYWORDS
PAPER SUBMITTED: 2014-05-03
PAPER REVISED: 2014-06-29
PAPER ACCEPTED: 2014-08-03
PUBLISHED ONLINE: 2014-09-06
DOI REFERENCE: https://doi.org/10.2298/TSCI140503105S
CITATION EXPORT: view in browser or download as text file
THERMAL SCIENCE YEAR 2016, VOLUME 20, ISSUE Issue 5, PAGES [1555 - 1564]
REFERENCES
  1. Akachi, H., et al., Pulsating Heat Pipes, Proceedings, 5th Intl. Heat Pipe Symp., Melbourne, Australia, 1996, pp. 208-217
  2. Maezawa, S., et al., Thermal Performance of Capillary Tube Thermosyphon, Proceedings, 9th Intl. Heat Pipe Conf., Albuquerque, N. Mex., USA, 1995, pp. 791-795
  3. Xu, J. L., et al., High Speed Flow Visualization of a Closed Loop Pulsating Heat Pipe, Heat Mass Transfer, 48 (2005), pp. 3338-3351
  4. Soponpongpipat, N., et al., Investigation of the Startup Condition of a Closed Loop Oscillating Heat Pipe, Heat Transfer Eng., 30 (2009), 8, pp. 626-642
  5. Charoensawan, P., et al., Closed Loop Pulsating Heat Pipes – Part A: Parametric Experimental Investigations, Appl. Therm. Eng., 23 (2003), 16, pp. 2009-2020
  6. Khandekar, S., et al., Closed Loop Pulsating Heat Pipes – Part B: Visualization and Semi-Empirical Modeling, Appl. Therm. Eng., 23 (2003), 16, pp. 2021-2033
  7. Zhang, X. M., Experimental Study of a Pulsating Heat Pipe Using FC-72, Ethanol, and Water as Working Fluids, Exp. Heat Transfer, 17 (2004), 1, pp. 47-67
  8. Charoensawan, P., Terdtoon, P., Thermal Performance of Horizontal Closed-Loop Oscillating Heat Pipe, Appl. Therm. Eng., 28 (2008), 5-6, pp. 460-466
  9. Sakulchangsatjatai, P., et al., Operation Modeling of Closed-End and Closed-Loop Oscillating Heat Pipes at Normal Operating Condition, Appl. Therm. Eng., 24 (2004), 7, pp. 995-1008
  10. Kammuang-Lue, N., et al., Effect of Working Fluids on Thermal Effectiveness of Closed-Loop Pulsating Heat Pipe Applied in Ice Storage System, Proceedings, 8th Intl. Heat Pipe Symp., Kumamoto, Japan, 2006, pp. 323-328
  11. Kammuang-Lue, N., et al., Effect of Working Fluids on Thermal Characteristic of a Closed-Loop Pulsating Heat Pipe Heat Exchanger: A Case of Three Heat Dissipating Devices, Proceedings, IEEE 14th Electronics Packaging Technology Conf., Singapore, 2012, pp. 142-147
  12. Charoensawan, P., et al., Effect of Evaporator Section Lengths, Number of Turns and Working Fluid on Internal Flow Patterns of a Vertical Closed-Loop Oscillating Heat Pipe, Proceedings, 7th Intl. Heat Pipe Symp., Jeju, Korea, 2003, pp. 360-367
  13. Khandekar, S., et al., Understanding Operational Regimes of Closed Loop Pulsating Heat Pipes: An Experimental Study, Appl. Therm. Eng., 23 (2003), 6, pp. 707-719
  14. Charoensawan, P., et al., Effect of Inclination Angles, Filling Ratios and Total Lengths on Heat Transfer Characteristics of a Closed-Loop Oscillating Heat Pipe, Proceedings, 6th Intl. Heat Pipe Symp., Chiang Mai, Thailand, 2000, pp. 421-430
  15. Zhang, Y., Faghri, A., Heat Transfer in a Pulsating Heat Pipe with Open End, Heat Mass Transfer, 45 (2002), 4, pp. 755-764
  16. Groll, M., Khandekar, S., Pulsating Heat Pipes: Progress and Prospects, Proceedings, Intl. Conf. on Energy and the Environment, Shanghai, China, 2003, Vol. 1, pp. 723-730
  17. Shafii, M. B., et al., Thermal Modeling of Unlooped and Looped Pulsating Heat Pipes, ASME J. Heat Transfer, 123 (2001), 6, pp. 1159-1171
  18. Shafii, M. B., et al., Analysis of Heat Transfer in Unlooped and Looped Pulsating Heat Pipes, Intl. J. Numerical Methods for Heat and Fluid Flow, 12 (2002), 5, pp. 585-609
  19. Sriwiset, C., et al., Evaluation of Optimum Turn Number for Closed-Loop Pulsating Heat Pipe at Normal Operation, Proceedings, 5th Intl. Conf. on Science, Technology and Innovation for Sustainable Well-Being, Luang Prabang, Lao PDR, 2013, pp. MME06 1-5

© 2024 Society of Thermal Engineers of Serbia. Published by the Vinča Institute of Nuclear Sciences, National Institute of the Republic of Serbia, Belgrade, Serbia. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International licence