A NEW DEFINITION OF BEJAN NUMBER

ABSTRACT
A new definition of Bejan number will be generated by replacing the thermal diffusivity with the mass diffusivity. For example, the Schmidt number is the mass transfer analog of the Prandtl number. For the case of Reynolds analogy (Sc = Pr = = 1), both current and new definitions of Bejan number are the same. This new definition is useful and needed for diffusion of mass (mass diffusion).
KEYWORDS
PAPER SUBMITTED: 2012-08-03
PAPER REVISED: 2012-08-04
PAPER ACCEPTED: 2012-08-08
DOI REFERENCE: https://doi.org/10.2298/TSCI12041251A
CITATION EXPORT: view in browser or download as text file
THERMAL SCIENCE YEAR 2012, VOLUME 16, ISSUE Issue 4, PAGES [1251 - 1253]
REFERENCES
  1. Bhattacharjee, S., Grosshandler,W. L., The Formation of a Wall Jet Near a High Temperature Wall under Microgravity Environment, Proceedings, ASME 1988 National Heat Transfer Conference, Houston, Tex., USA, 1988, Vol. 1 (A89-53251 23-34), pp. 711-716
  2. Petrescu, S., Comments on the Optimal Spacing of Parallel Plates Cooled by Forced Convection, International Journal of Heat and Mass Transfer, 37 (1994), 8, pp. 1283
  3. Bejan, A., Sciubba, E., The Optimal Spacing of Parallel Plates Cooled by Forced Convection, International Journal of Heat and Mass Transfer, 35 (1992), 12, pp. 3259-3264
  4. Bejan, A., Heat Transfer, John Wiley and Sons Inc., New York, USA, 1993
  5. Bejan, A., Single Correlation for Theoretical Contact Melting Results in Various Geometries, International Communications in Heat and Mass Transfer, 19 (1992), 4, pp. 473-483
  6. Fowler, A. J., Ledezma, G. A., Bejan, A., Optimal Geometric Arrangement of Staggered Plates in Forced Convection, International Journal of Heat and Mass Transfer, 40 (1997), 8, pp. 1795-1805
  7. Bejan, A., Optimal Spacing for Cylinders in Crossflow Forced Convection, ASME Journal of Heat Transfer, 117 (1995), 3, pp. 767-770
  8. Stanescu, G., Fowler, A. J., Bejan, A.,The Optimal Spacing of Cylinders in Free-Stream Cross-Flow Forced Convection, International Journal of Heat and Mass Transfer, 39 (1996), 2, pp. 311-317
  9. Ledezma, G. A., Morega, A. M., Bejan, A., Optimal Spacing between Fins with Impinging Flow, ASME Journal of Heat Transfer, 118 (1996), 3, pp. 570-577
PDF VERSION [DOWNLOAD]

© 2024 Society of Thermal Engineers of Serbia. Published by the Vinča Institute of Nuclear Sciences, National Institute of the Republic of Serbia, Belgrade, Serbia. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International licence