THERMAL SCIENCE

International Scientific Journal

External Links

INFLUENCE OF INITIAL BED TEMPERATURE ON BED PERFORMANCE OF AN ADSORPTION REFRIGERATION SYSTEM

ABSTRACT
The study deals with the complete dynamic analysis (numerical and practical) of an existing adsorption refrigeration system. The adsorption refrigeration setup is available at Indian School of Mines (Dhanbad, India) Mechanical engineering department. The system operates with activated carbon (as an adsorbent) and methanol (as refrigerant).Numerical model is established base on energy equation of the heat transfer fluid (water) and transient heat and mass transfer equations of the adsorbent bed. The input temperature of heat source is 90°C, which is very low compared to other low-grade energy input refrigeration system. The thermo-physical properties of an adsorptive cooling system (using activated carbon-methanol pair) are considered in this model. In this analysis influence of initial bed temperature (T1) on the bed performances are analysed mathematically and experimentally. The simulation and practical results of this system show that the cycle time decreases with increase in initial bed temperature and the minimum cycle time is 10.74 hours (884min for practical cycle) for initial bed temperature of 40°C.Maximum system COP and specific cooling capacity are 0.436 and 94.63kJ/kg of adsorbent under a condenser and evaporator temperatures of 35°C and 5°C, respectively. This analysis will help to make a comparison between simulated and experimental results of a granular bed adsorption refrigeration system and also to meet positive cooling needs in off-grid electricity regions.
KEYWORDS
PAPER SUBMITTED: 2016-01-08
PAPER REVISED: 2016-09-29
PAPER ACCEPTED: 2016-10-14
PUBLISHED ONLINE: 2016-11-06
DOI REFERENCE: https://doi.org/10.2298/TSCI160108254S
CITATION EXPORT: view in browser or download as text file
THERMAL SCIENCE YEAR 2018, VOLUME 22, ISSUE Issue 6, PAGES [2583 - 2595]
REFERENCES
  1. Habib, K., et al. Study of various adsorbente-refrigerant pairs for the application of solar driven adsorption cooling in tropical climates,Applied Thermal Eng, 72(2014), pp. 266-74.
  2. Wang, L.W., et al. The performance of two adsorption ice making test units using activated carbon and a carbon composite as adsorbents,Carbon 44 (2006), pp. 2671-80.
  3. Naef, A.A.,al. Thermal analysis and modeling study of an activated carbon solar adsorption ice maker, Energy Conversion and Management,100 (2001), pp. 310-323.
  4. Hassan, H.Z, Mohamad, A.A., Thermo dynamic analysis and theoretical study of a continuous operation solar-powered adsorption refrigeration system, Energy 61 (2013),pp.167-178.
  5. Sur, A, Randip, K.D., Numerical Modeling and Thermal Analysis of an Adsorption Refrigeration System, International Journal of Air-Conditioning and Refrigeration 23 (2015), 4, pp.15500331-11.
  6. Chekirou, W., et.al. Dynamic modelling and simulation of the tubular adsorber of a solid adsorption machine powered by solar energy,Int J Refrig.39 (2014), pp.137-51.
  7. Gaglino A, Patania F, Nocera F, Galesi A, performance assesment of a solar assisted desiccant cooling system, Thermal Science 18 (2014), 2, pp. 563-576.
  8. Jani D B, Mishra.M, Sahoo P K, Solid desiccant air conditionig - A state of the art review, Renewable and sustainable energy 60 (2016), pp. 1451-1469

© 2024 Society of Thermal Engineers of Serbia. Published by the Vinča Institute of Nuclear Sciences, National Institute of the Republic of Serbia, Belgrade, Serbia. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International licence