Thermal performance investigation of an aluminum fanless thermal storage indoor heat exchanger under multiple operation parameters: An experimental and numerical study

ABSTRACT
The direct-condensation indoor heat exchanger was an effective heating method for winter heating. However, the metal thermal strength and pressure-bearing capacity of the previous steel panel were weaker than that of aluminum materials. Consequently, a novel aluminum fanless thermal storage indoor heat exchanger (AHE) is proposed for the air-source heat pump (ASHP) heating system. The model is established to explore the heating performances of the novel direct-condensation indoor heat exchanger. Compared with experimental data, the deviation of the predicted heat dissipation changes from -2.4% and 3.6%, verifying the model's reliability. To investigate the thermal potentials of the AHE under multiple operation parameters, a total of 66 cases were conducted. Results show that the ascendant condensation temperature and refrigerant flow rate are beneficial for the improvement of the heat exchange performance. Meanwhile, the increased condensation temperature also contributes to decreasing flow losses. In simulations, the average temperature difference between the refrigerant and panel surface is 9.7ºC. The maximum temperature difference of adjacent layers of the AHE is 6.3ºC, occurring between the copper tube and the water layer. Based on the simulated values, a thermolysis correlation was proposed for the AHE to predict the heat dissipation under multiple operation parameters. This study provides a stable and reliable direction-condensation heating terminal for ASHP systems. The results of this study are beneficial for the promotion and application of the direction-condensation heating terminal.
KEYWORDS
PAPER SUBMITTED: 2024-05-27
PAPER REVISED: 2025-01-26
PAPER ACCEPTED: 2025-02-02
PUBLISHED ONLINE: 2025-03-08
DOI REFERENCE: https://doi.org/10.2298/TSCI240527029S
REFERENCES
  1. International Energy Agency. IEA (2023), Energy Statistics Data Browser, IEA, Paris www.iea.org/data-and-statistics/data-tools/energy-statistics-data-browser
  2. Zhao X, M X W, Chen B Y, Shang Y P, Song M L. Challenges toward carbon neutrality in China: Strategies and countermeasures [J]. Resources, Conservation and Recycling, 2022, 176, 105959
  3. Tanabe S, Kimura K. Importance of air movements on thermal comfort under hot and humid conditions [C]. Proceedings of the Second ASHRAE Far East Conference on Air Conditioning in Hot Climates, Kuala Lumpur: ASHRAE, 1989, 95-103
  4. Chen shouhai, Gao tong, Wang jun, Wang hongchao. Research on temperature field characteristics and thermal comfort of wall type frequency conversion air conditioner [J]. China Academic Journal Electronic Publishing House. 2018, 147-151
  5. HUANG Yunqi,SITU Shan shan,CHEN Xiaohui.Experimental Study on Optimal Air Temperature for Wall-Mounted Air Conditioning Heating Comfort [J].Environmental Technology, 2019,37(03):64-69.
  6. Olesen B. Comparative Experimental Study of Performance of Radiant Floor- Heating Systems and a Wall Panel Heating System Under Dynamic Conditions [J]. ASHRAE Transactions, 1994, 100(1): 1011-1023
  7. Xiao B, He L, Zhang S H, et al. Comparison and analysis on air-to-air and air-to-water heat pump heating systems [J]. Renewable Energy, 2020, 146(2): 1888-1896
  8. Zhang H, Jiang L F, Zheng W D, et al. Experimental study on a novel thermal storage refrigerant-heated radiator coupled with air source heat pump heating system [J]. Building and Environment, 2019, 164(15): 106341
  9. Zeng zhangchuan. Thermodynamics Analysis and Heat Transfer Research of Direct Radiant Floor Heating System with ASHP [D].China, Zhenzhou: Zhengzhou University,2010.
  10. Wang yuanyuan, Zhang chao,liang nianliang,et al. Research status of air source heat pump refrigerant direct heating system for building heating [J].Building Energy Efficiency, 2015, 43(07): 21-24.
  11. Dong J K, Zhang L, Deng S M, et al. An experimental study on a novel radiant-convective heating system based on air source heat pump [J]. Energy and Buildings, 2018, 158(1): 812-821
  12. Shao Suola, Zhang Huan, You Shijun, Wang Yaran. Experimental investigation of air-source heat pump heating system with a novel thermal storage refrigerant-heated panel [J]. Journal of Thermal Science and Engineering Applications, 2021, 139(1): 011015
  13. Debabrata Pal, Nasim Hasan, Pabbathi Vijaya Rao, Nagarajan. Temperature distribution analysis of Cu, Al and steel material heat exchangers by ANSYS [J]. Materials Today: Proceedings, 2022, 56: 3176-3185
  14. He B H, Li L L, He G C. Experimental study on heat transfer performance of micro-grooved I-shaped aluminum heat pipe for heat pipe heat exchangers [J]. Applied Thermal Engineering, 2024, 253: 123733
  15. Arima H, Nishiguchi M, Suehiro S. Effect of the surface form of the herringbone aluminum plate in a plate heat exchanger on the boiling heat transfer performance of ammonia [J]. Applied Thermal Engineering, 2024, 256: 124057
  16. Guo X, Wei H B, He X, et al. Experimental evaluation of an earth-to-air heat exchanger and air source heat pump hybrid indoor air conditioning system [J]. Energy and Buildings, 2022, 256: 111752
  17. Yang J M, Cao H Q, Wang Z W, et al. Direct-supply chilled-water radiant-floor cooling system coupled with an earth‒air heat exchan er system: A case study in a building [J]. Case Studies in Thermal Engineering, 2025, 65: 105586
  18. Shao S L, Xu C C. Performance Analysis of Novel Direct-Condensation Heating Panels Integrated with Air Source Heat Pump System on Thermal Economy and System Efficiencies [J]. Energies, 2024, 17(18): 4561
  19. Shao S L, Zhang H, You S J, et al. Thermal performance analysis of a new refrigerant-heated radiator coupled with air-source heat pump heating system [J]. Applied Energy, 2019, 247: 78-88
  20. Shao S L, Zhang H, You S J, et al. Prediction of thermal potentials of multi-panel refrigerant heated radiator based on a mathematical model considering refrigerant flow distribution[J]. Energy & Buildings, 2020, 228: 110446
  21. Gnielinski V. New equations for heat and mass transfer in turbulent pipe and channel flow [J]. International Chemical Engineering, 1976, 16: 359-368
  22. Dittus F W, Boelter L M K. Heat transfer in automobile radiators of the tubular type [J]. International Communications in Heat & Mass Transfer, 1985, 12(1): 3-22
  23. William A D, Pega H. Heat transfer and flow regimes during counter-flow steam condensation in flattened-tube air-cooled condensers [J]. International Journal of Heat and Mass Transfer, 2020, 147: 118930
  24. John H. A heat transfer textbook, 4th edition [M]. USA: Phlogiston Press, 2018: 141-160, 523-577
  25. Tari I, Mehrtash M. Natural convection heat transfer from inclined plate-fin heat sinks [J]. InternationalJournal of Heat and Mass Transfer, 2013, 56(1-2): 574-593
  26. Kraus A D, Aziz A, Welty J. Extended Surface Heat Transfer [M]. USA: Library of Congress, 2001: 58-92, 170-193
  27. Yang ZQ, Gong MQ, Chen CF, Zou X, Shen J. Two-phase flow patterns, heat transfer and pressure drop characteristicsof R600a during flow boiling inside a horizontal tube [J]. Applied thermal engineering, 2017(120), 654-671
  28. Moody L F. Friction factors for pipe flow [J]. Transactions on ASME 1944, 66: 671-684
  29. Kim S M, Mudawar I. Universal approach to predicting two-phase frictional pressure drop for adiabatic and condensing mini/micro-channel flows [J]. International Journal of Heat and Mass Transfer, 2012, 55(11-12): 3246-3261
  30. General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, National Standardization Administration of China. GB/T 13754-2017 Test methods of thermal output of heating radiators [S]. Beijing: China Standards Publishing House, 2018