THERMAL SCIENCE
International Scientific Journal
EXPERIMENTAL EVALUATION OF THE THERMAL CHARACTERISTICS OF R417A USED IN AIR SOURCE HEAT PUMP WATER HEATERS
ABSTRACT
In this paper, experiments were conducted to compare the thermodynamic performance of R417A used in air-source heat pump water heaters under two ambient temperature conditions of 20°C and 7°C, including discharge pressure, input power and COP, and the experimental results were analyzed. The results showed that the operation was reliable and that R417A is very suitable for heat pump water heaters. This study provides a promising alternative refrigerant to freon.
KEYWORDS
PAPER SUBMITTED: 2024-04-15
PAPER REVISED: 2024-05-30
PAPER ACCEPTED: 2024-05-30
PUBLISHED ONLINE: 2025-07-06
THERMAL SCIENCE YEAR
2025, VOLUME
29, ISSUE
Issue 3, PAGES [1685 - 1692]
- Chinnasamy, S., et al., Solar-Air Source Heat Pump Water Heater for Scorching Climatic Condition: Energy, Exergy, Economic and Enviroeconomic (4E) Exploration for Sustainable Future, Applied Thermal Engineering, 240 (2024), 122212
- Xu, Y. C., et al., Feasibility Study of an Integrated Air Source Heat Pump Water Heater/Chillers and Exhaust Gas Boiler Heating System for Swimming Pool on Luxury Cruise Ship, Energy Report, 8 (2022), Nov., pp. 1260-1282
- Liu, X., et al., A Novel Testing and Theoretical Approach for Air-Source Heat-Pump Water Heater with Flash Tank Vapor-Injection, Res. Express, 4 (2022), 045030
- Li, J., et al., Technical and Economic Performance Study on Winter Heating System of Air Source Heat Pump Assisted Solar Evacuated Tube Water Heater, Applied Thermal Engineering, 221 (2023), 119851
- Du, Y. J., et al., Research on Control Method of a R290 ASHP under Low-Temperature Heating Condition, International Journal of Refrigeration, 129 (2021), Sept., pp. 60-68
- Qi, Z. G., Experimental Investigation on Minichannel Parallel Flow Condenser Performance with R22, R410A and R407C, International Journal of Refrigeration-Revue Internationale du Froid, 72 (2016), Dec., pp. 74-80
- Jin, Z. Q., et al., Annual Energy Performance of R744 and R410A Heat Pumping Systems, Applied thermal Engineering, 117 (2017), May, pp. 568-576
- Liu, Z. L., et al., Performance Comparison of Air Source Heat Pump with R407C and R22 under Frosting and Defrosting, Energy Conversion and Management, 49 (2008), 2, pp. 232-239
- Zuo, Y. T., Variational Principle for a Fractal Lubrication Problem, Fractals, On-line first, doi.org/10.1142/S0218348X24500804, 2024
- Cao, F., et al., Experimental Analysis of Mass Composition of R417A in Presence of Leak/Recharge in a Heat Pump Water Heater, Journal of Energy Resources Technology 131(2009), 4, 042401
- Chen, J. B., et al., Comparison of Performance between R290 and R417A in Heat Pump Air Conditioning Water Heater Combination, Advanced Materials Research, 243-249 (2011), 1269, pp. 4918-4922
- Zhao, L., et al., Promises and Challenges of Fractal Thermodynamics, Thermal Science, 27 (2023), 3A, pp.1735-1740