TY - JOUR TI - Influencing law of key parameters on the thermal efficiency of single-well closed-loop heat exchanger AU - Li Jing-Bin AU - Wang Hao AU - Li Huan AU - Guo Chenrui AU - Yang Dong JN - Thermal Science PY - 2024 VL - 28 IS - 2 SP - 1037 EP - 1043 PT - Article AB - The single-well closed-loop heat extraction technology can realize efficient exploitation of mid-to-deep geothermal resources. A two-dimension heat transfer model is established. The effects of flow rate, inlet temperature, length and diameter of insulated tubing on heat extraction power and outlet temperature were investigated by the two-way absolute grey correlation analysis method. Results indicate that thermal power increases with the increase of displacement and length of insulated tubing, and decreases with the increase of injection temperature, outer diameter of insulated tubing and inner diameter of insulated tubing.