TY - JOUR TI - A system to monitor and model the thermal isolation of coating compounds applied to closed spaces AU - Montes Frank Florez AU - Fernández De Córdoba Pedro AU - Calvet José Luis Higón AU - Conejero J. Alberto AU - Poza-Luján José-Luis JN - Thermal Science PY - 2020 VL - 24 IS - 3 SP - 1885 EP - 1892 PT - Article AB - Smart control systems and new technologies are necessary to reduce the energy consumption in buildings while achieving thermal comfort. In this work, we monitor the thermal evolution inside a scale reduced closed space whose exterior and/ or interior wall faces have been painted with a coating solution. Based on the experimental data obtained under different environmental conditions, a simulator was developed and tuned to reproduce the thermodynamic behavior inside the spaces, with a relative error of less than 3.5%. This simulator lets us also estimate energy savings, temperature, and flux behavior under other conditions.